Interface Cable for RS-422/ RS-485
To control the Apollo by RS-422/ RS-485 interface, only the signals TDATA+,
TDATA-, RDATA+, and RDATA- are necessary.
Check the pin assignment of the interface of your computer, and use the pin
assignment of the printer as shown in Table B-1 to obtain a suitable cable.
The pins of TDATA+ and RDATA+ and the pins of TDATA- und RDATA- have
to be connected with ea ch other. For long transmission distances it is
recommanded to terminate the lines.
9 pin connector 25 pin plug
Fig. B-5 Interface cable with 9 pin computer connector
for RS-232 with protocol "RTS/CTS" or "XON/XOFF"
25 pin connector 25 pin plug
Fig. B-4 Interface cable with 25 pin computer connector
for RS-232 with protocol " RTS/CTS" or "XON/XOFF"
PC Apollo
11
23
32
45
54
77
6
8
20
PC Apollo
22
33
57
75
84
1